A tripped MCB (Miniature Circuit Breaker) will be in a position between on and off, or clearly in the off position. Before resetting it, you must identify and remove the cause of the trip — resetting without doing so will simply cause it to trip again immediately, or worse, allow a fault to persist. Unplug all appliances on the circuit before attempting a reset.
To reset an MCB: first switch it fully to the off position (if it is in a middle position), then switch it back to on. If it immediately trips again with no appliances connected, there may be a wiring fault on the circuit — do not keep resetting it. Call a qualified electrician to investigate.
If the MCB holds after resetting with no appliances connected, plug appliances back in one at a time to identify the faulty one. The circuit will trip again when you plug in the faulty appliance. A frequently tripping MCB on a loaded circuit (where no individual appliance is faulty) suggests the circuit is overloaded and needs additional capacity.
RCDs trip differently from MCBs — they have a test button and typically reset with a push-to-reset button or a toggle switch. If an RCD trips and will not reset, there is a persistent earth fault on one of the circuits it protects. Systematically disconnect each circuit and attempt a reset to identify the faulty circuit, then call an electrician. Never bypass or replace an RCD with a standard MCB.